Galaxy Flex Installer Manual Engineer Access [48, Quick Menu 9]69Engineer Access [48, Quick Menu 9]This option enables a manager to authorize an engineer to access the system.Engineer System Access [48.1.1]By default the assigned engineer code is programmed as dual. This prevents the engineerfrom accessing engineering mode unless authorized to do so by a type 6 user, normally amanager with a valid code.To authorize an engineer to access the system:1. Enter your code.2. Press 48 ent 1 ent 1 ent.3. Press 1 ent to enable engineer access.4. Press and hold esc to return to the banner.This provides a five minute period during which the engineer can access engineering modewithout causing a tamper alarm. Once in engineering mode there is no time limit on theaccess period.User authorization is limited to one visit only. When you return the system to user mode, theauthorization is still valid for five minutes. After this time it must be granted again by themanager.Limited SIA Access [48.2.0]Use this option to allow a SIA level 4 user to send commands to the control panel, butexclude resetting of the panel after an alarm signal.Full SIA access [48.2.1]Use this option to allow a SIA level 4 user to send commands to the control panel. The usercan reset the panel after an alarm signal.