Galaxy Flex Installer Manual Keypad menu timeout29Keypad menu timeoutIf you do not use the keypad for 5 minutes the system reverts to displaying the banner text.This does not apply if you are logged in as Engineer (type 7).Note: In the Walk Test option the timeout is 20 minutes if no zones are tested or no keysare pressed. In 66=PRE-CHECK the timeout is 20 minute after the last zone hasbeen activated.Engineer ModeTo program the control panel, the system must be in engineering mode, allowing access tomenu options 50=ENGINEER 1, 60=ENGINEER 2 and 70=ENGINEER 3.If you are setting up and programming a control panel prior to handover, use the followingprocedure to access engineering mode.To enter Engineer Mode:1. Enter the default manager code, and then press ent.2. Press 48 ent 1 ent 1 ent 1 ent to enable Engineer Mode. You have 5 minutes to carryout the next step.3. Enter the default engineer code, and then press ent.After handover the codes should have been changed and you will need to get a manager orother type 6 user to carry out steps 1 and 2. See Engineer Access [48] for more details.On accessing engineering mode, any group that is set becomes inaccessible. Set groupscannot be assigned to zones, outputs and any other functions permitting group allocation.When the engineer code is entered three things happen: All system tampers become isolated. You gain access to the full menu. The banner message is changed to indicate engineer mode.To exit from Engineer Mode:1. Return to the engineer banner.2. Enter your engineer code.3. Press esc.Note: If esc is pressed during the following system checks, the exit is aborted and thesystem remains in engineering mode.Before the normal banner is displayed the system performs these checks: That there are no open zones or tampers. If there are tampers, they are displayed toallow investigation. Open zones are not displayed.