Galaxy Flex Installer Manual Override faults and tampers35determined on site. The cause code values should be determined in conjunction with theAlarm Receiving Centre (ARC).Override faults and tampersWhenever a user logs in, the display shows any unrestored faults and tampers. If thecondition cannot be cleared and restored, the user may be able to override the condition.When a user tries to set the system, any conditions that are present are displayed. The usercan scroll through multiple conditions. If the user has the authority to override the condition,the following display accompanies the condition:If the user cannot override the condition, ENT to Continue will not be displayed.The user can override each authorized condition by pressing ent while the condition isdisplayed on the keypad. Each condition is individually displayed and overridden.Pressing ent omits the condition for one set period only.Pressing esc returns to the previous banner.When setting the system with an overridden fault or tamper condition, the display indicatesthe overridden function in place of the set mode by showing the omit message as detailed inthe omit menu function. The Override condition is logged, and will last for one set periodonly. When all the groups that are affected by the override condition become unset, theoverride status is cleared. An override restore is logged at unset.If, during a setting attempt, there are conditions that haven’t restored and cannot beoverridden, then the system will not set. The display shows the CALL MANAGERRESET REQUIRED banner with a short beep every 30 seconds.Setting featuresThe control panel provides a range of features to help the user to set and unset the system.Show set statusEnsure that Show Status is enabled (refer to Show Status [58.6]). Press and #simultaneously to show the group set status.F = FaultR = ReadyS = SetP = Part SetL = Locked Out– = Group not assigned to keypadNote: The Show Status indicates the set conditions of groups when the system is set(keypad blank) or unset (normal banner). Show Status does not operate whileengineer mode is accessed.STATUS 12345678Groups RRSRLPFPALERT-BATT LOWent=CONTINUE SETgroup block