Galaxy Flex Installer Manual Display Zones [21, Quick Menu 2]41Display optionsDisplay Zones [21, Quick Menu 2]When you select Display Zones the first zone in the system is displayed. Press A or B todisplay other zones, or enter a zone number directly.The top line displays: the address. the group assigned, if the group mode is enabled. Only the zones assigned to the user’sgroup are displayed. the zone function alternating with the status: open, closed, high resistance, lowresistance, tamper short or tamper open circuit or masked.The bottom line displays the zone descriptor (if used).Press # to toggle the bottom line information: If the zone is a hardwired RIO, the circuit resistance in ohms and the RIO (not zone)voltage is displayed. Press # twice to display the maximum (+) and minimum (−) zoneresistance for a particular day. Use A or B to scroll through stored values for the past 14days. If the zone is an RF zone, the highest and lowest signal strength, and the address of theRF Portal with which it is communicating is displayed.Press to get a printout of all the zones. Press esc to abort the printout.Note: A printer must be connected to the panel via a printer interface module.Display Log [22, Quick Menu 3]Use this option to view the event log. Flex panels can store 1000 events.The alarm log uses a FIFO (First In, First Out) method to log and store alarms. The controlpanel differentiates between mandatory and non-mandatory events. All events are logged,however, when the log becomes full, non-mandatory events are dropped first. The log willalways contain at least 500 mandatory events (assuming 500 or more mandatory events havebeen generated). A full list of EN50131-1 mandatory events and non-mandatory eventslogged by the panel is given in Appendix B: SIA and contact ID event codes.Note: The number of events logged from any one source during any set/unset period iscontrolled by the Alarm Limits [51.48] parameter.If group mode is enabled (refer to Options [63]) and the user code has group choice (refer toCodes [42]), the available groups are displayed for selection. Press the number of the groupsto be displayed, the N below the selected group changes to a flashing Y. When all therequired groups are selected press ent to access the log. Only the events in the selectedgroups are displayed.