Omit Zones [11, Quick Menu 0] Galaxy Flex Installer Manual38Menu Options 11-19Omit Zones [11, Quick Menu 0]Use this option to remove (omit) zones from the system temporarily. Once a zone has beenomitted it does not generate an alarm condition (including tamper). Omitted zones arereinstated automatically when the system is unset or reinstated manually when the zone omitoption is disabled.On selecting the Omit Zones option, the first zone that has the omit attribute enabled isdisplayed (refer to Program Zones [52]). If there are no omittable zones, then the messageNO ENTRIES is displayed.Scroll to the zone you want to omit, and then press # to toggle the omit status. The displayindicates the new omit status.Note: A zone is omitted from the system as soon as it is selected.Repeat this process to omit more zones if required, and then do one of the following: press ent to start the timed setting routine. The number of zones omitted from thesystem is displayed during the exit time countdown; press esc to return to 11=OMIT ZONES without starting the setting routine.On returning to the banner (normal or engineer) the keypad displays the message ZONESOMITTED.Outputs programmed as Zone Omit (mode programmed as reflex) are activated as soon asthe zone is omitted and remain active until the zone is reinstated.Manually reintroduce omitted zonesSelect the OMIT ZONES option.Select the omitted zone to be reinstated, and then press # to toggle the omit status of therequired zone. The display indicates the new omit status.Normal Setting with omitted zonesInitiate the full or part setting routine. The system starts to set, and the display indicates thatzones have been omitted. The zone remains omitted until the system is unset.Timed Set [12]This option starts the setting routine. The entry/exit horns emit the expiry warning using theprogrammed exit time (0-300 seconds). The system sets at the end of the exit time or earlierif a final zone is opened and closed, key 0 is pressed if programmed as an exit terminator, orif a push-set terminator is operated. The option displays the time remaining until the systemsets or the number of open zones preventing the system from setting. Opening a zone duringthe exit routine resets the exit timer. Pressing esc prior to the system setting aborts thesetting routine.