71 Stop BitThis item lets you set the number of stop bits for RS-232Ccommunication.1. Move the cursor to the STOP BIT parameter by press-ing the D or C button.2. Select either 1 or 2 for the number of stop bits by press-ing the + or - button.The factory default setting is 1 bit. Wait TimeThis item lets you set the waiting time in milli-seconds (ms)to retry after confirming that no data is received from thecontroller for RS-232C communication.1. Move the cursor to the WAIT TIME parameter by press-ing the D or C button.2. Select OFF, 100, 200, or 1 000 ms for the wait time bypressing the + or - button.When no transmission is needed, select OFF.The factory default setting is OFF (no retry). Network SetupWhen the optional Network Board is installed in the DiskRecorder, the Disk Recorder can be controlled from aClient PC via the Ethernet Hub.These items let you set the parameters for communicationbetween the 10/100BASE-T port of the Disk Recorder andoutboard device via Ethernet.1. Set DHCP (Dynamic Host Configuration Protocol) to ONor OFF.The default setting is OFF.ON: Uses DHCP. The DHCP server will assign the net-work parameters.OFF: Does not use DHCP. You need to enter the follow-ing parameters if you wish to change them from thedefault settings.2. Move the cursor to IP ADDRESS in the COMMUNICA-TION SETUP menu by pressing the C or D button,then press the SET button.The cursor moves to the right editing area.3. Select the value for the IP Address by pressing the +or - button.4. Move the cursor to the right by pressing the B button,then select the value for the IP Address by pressing the+ or - button.5. Repeat the above steps 2 and 3 until the IP Address iscompleted.6. When the IP Address is completed, press theSETUP/ESC button to return the cursor to IP ADDRESSin the menu.7. Similarly repeat the above steps 1 to 5 to set theNetmask and Gateway.8. To return to the previous setup menu, press theSETUP/ESC button.