70 Baud RateThis item lets you set the transmission speed for RS-232Ccommunication.1. Move the cursor to the BAUD RATE parameter bypressing the D or C button.2. Select the desired transmission speed shown below bypressing the + or - button.The factory default setting is 9 600 bps. Data BitThis item lets you set the number of data bits for RS-232Ccommunication.1. Move the cursor to the DATA BIT parameter by press-ing the D or C button.2. Select either 7 or 8 for the number of data bits by press-ing the + or - button.The factory default setting is 7 bits. Parity CheckThis item lets you set the parity bit for RS-232C communica-tion.1. Move the cursor to the PARITY CHECK parameter bypressing the D or C button.2. Select NONE, EVEN or ODD for parity check by press-ing the + or - button.The factory default setting is ODD. RS-232C SetupThese items let you set the parameters for communicationbetween the SERIAL port of the Disk Recorder and anexternal device.1. Move the cursor to RS232C SETUP in the COMMUNI-CATION SETUP menu by pressing the C or D button,then press the SET button.The RS232C SETUP menu shown below appears on themonitor screen.2. Select an item parameter in the menu by pressing theD or C button.3. To return to the previous setup menu, press theSETUP/ESC button. Unit Address SettingThis item lets you set the unit address of the Disk Recorderin the system.1. Move the cursor to the UNIT ADDRESS parameter bypressing the D or C button.2. Select the unit address number to be used for RS-232Ccommunication by pressing the + or - button.Select a parameter value between 001 and 099.The factory default setting is 001.8-2 RS232C SETUPUNIT ADDRESS 001BAUD RATE 9600DATA BIT 7PARITY CHECK ODDSTOP BIT 1WAIT TIME OFF↔ 2 400 ↔ 4 800 ↔ 9 600 ↔19 200 ↔ 38 400 ↔