52 External Program TimerThe internal timer can be changed to the specified timerpreviously programmed by the input from the externaltimer. This function is enabled, when a contact is connect-ed with pin 22 of the ALARM port.This item lets you enable or disable the external timer forrecording.1. Move the cursor to the EXT REC MODE parameter inthe TIMER REC SETUP menu by pressing the D or Cbutton.2. Select the desired program to be changed by pressingthe + or - button.PROG1 - 4: Selects a timer assigned program number.--- : Disables the external program timer.The factory default setting is --- .3. Press the SET button to display the assigned programnumber menu previously programmed.If the program number menu has not been edited previ-ously, edit the assigned program number menu asdescribed before.4. Press the SETUP/ESC button to return to the previoussetup menu. Time Lapse Recording (InternalTimer)These items let you set the recording parameters for TimeLapse Recording assigned in the program number menu.(Continued from Program Timer)1. Select the recording mode T/L in the program numbermenu by pressing the + or - button, then press theSET button.The selected Time Lapse Recording menu shownbelow appears on the monitor screen.2. Move the cursor to the TIMER REC MODE parameter inthe menu by pressing the D or C button.3. Select the recording time mode to be set by pressingthe + or - button.OFF: Disables normal recording and enables onlyalarm recording.SF-✽✽H or SF-A*✽✽H: Selects the recording timemode in enhanced fine quality.FQ-✽✽H or FQ-A*✽✽H: Selects the recording timemode in fine quality.NQ-✽✽H or NQ-A*✽✽H: Selects the recording timemode in normal quality.EX-✽✽H or EX-A*✽✽H: Selects the recording timemode in extended quality.SP or SP-A*: Freely selectable✽✽ indicates the hours for recording time mode:2, 12, 18, 24, 48, 72, 96, 120, 180, 240, 360, 480,720, 960, 1200, 1440, 2160, 2880, 3600, 4320,6480, 8640(parameter A* indicates recording with audio)When the parameter SF/FQ/NQ/EX is selected forrecording time, the recording rate and quality are auto-matically set according to the selected recording time.Note: It may not be possible to set the recording time,depending on the remaining storage capacity of thehard disk.The factory default setting is SF-24H.4. If the parameter SP is selected for recording time, movethe cursor to the REC RATE parameter by pressing theD or C button, then select a recording rate by pressingthe + or - button.1 - 60FPS: Records the selected number of freezeimages every second.0.5FPS: Records a freeze image every 2 seconds.0.4FPS: Records a freeze image every 2.5 seconds.0.3FPS: Records a freeze image every 3.3 seconds.0.2FPS: Records a freeze image every 5 seconds.0.1FPS: Records a freeze image every 10 seconds.Notes:• The maximum recording rate depends on theselected parameters in the COMMON SETUP menuas shown in the table.FIELD/FRAME CAMERA GENLOCK REC RATEFIELD ON 60FPSOFF 30FPSFRAME 3DIM ON 10FPSON OFF 10FPSFRAME 3DIM ON 30FPSOFF OFF 15FPS3-1-1-1 PROG1-NO1-G1 REC SETUPT/L(TIME LAPSE)TIMER REC MODE SF- 24HREC RATE 7.5FPSQUALITY SUPER FINETRIGGER ACTION REC+ALMEVENT REC MODE SF- 24HREC RATE(MAX) 7.5FPSREC QUALITY SUPER FINEDURATION 10SDYNAMIC REC OFFREC RATE(BASE) 1FPSAUTO COPY OFF