87 Alarm SuspensionThis function disables the activation of the alarm link andinstead enables storing of any alarm activated in theERROR REPORT table.It is used to suspend the alarm link during the DiskRecorder’s setup.To suspend the alarm:1. Press the ALARM RESET and REC PREVIEW buttonsat the same time.The ALARM SUSPEND indicator lights to indicate thatthis function is selected.2. Press the ALARM RESET button to reset the alarm sus-pension.The ALARM SUSPEND indicator goes off. Alarm Reset Manual ResetWhen the alarm is activated, the ALARM indicator blinks.The indicator keeps blinking until all alarms are cleared bypressing the ALARM RESET button.The blinking or lit indicator goes off. Auto ResetThe alarm is automatically reset after the programmedalarm Auto Reset time has elapsed or the lost video signalhas been recovered.The ALARM indicator changes from blinking to a steadylight.Pressing the ALARM RESET button will clear the alarmand switch the indicator off. External ResetThe alarm is reset by a recovery signal received from theexternal equipment at pin 8 of the ALARM port located onthe rear of the Disk Recorder.The ALARM indicator changes from blinking to a steadylight.ALARMALARMRESETALARMRESETALARMSUSPENDALARMRESETALARMSUSPENDREC PREVIEW