OfficeServ 7100 PROGRAMMINGTECHNICAL MANUAL PART 2 APRIL 2007MMC: 204 COMMON BELL CONTROLDESCRIPTION:Determines whether the common bell relay contact has an interrupted orcontinuous closure when activated. If interrupted is chosen, the relay follows aninternal C.O. ring pattern of one second closed followed by three seconds open. Bydefault the common bell relay pair is assigned.PROGRAM KEYSUP & DOWN Used to scroll through optionsKEYPAD Used to enter selectionsSOFT KEYS Move cursorSPEAKER Used to store data and advance to next MMCACTION DISPLAY1. Press TRANSFER 204Display shows current setting[204] COM. BELLCONTINUOUS2. Dial common bell number [363] COM. BELLCONTINUOUS3. Dial 0 for continuous or 1 for interruptedoperation[363] COM. BELLINTERRUPTEDORUse UP or DOWN to scroll through optionsPress RIGHT soft key to return to step 2.4. Press TRANSFER to store and exitORPress SPEAKER to store and advance tonext MMC.DEFAULT DATA: CONTINUOUSRELATED ITEMS: MMC 203 ASSIGN UA DEVICEMMC 218 RELAY TYPEMMC 601 ASSIGN STATION GROUPMMC 724 MISC NUM PLAN