OfficeServ 7100 PROGRAMMINGTECHNICAL MANUAL PART 2 APRIL 2007MMC: 8524. Press UP or DOWN to select desired optionOR16:MJC05 AC:OFFAC Pwr LossPress TRANSFER to return to normal displayORpress SPEAKER to advance to next MMC.DEFAULT DATA: ALL OFFRELATED ITEMS MMC 501 SYSTEM TIMERS (ALARM REMINDER INTERVAL,ALARM REMINDER RING OFF TIMERS)MMC 722 STATION KEY ASSIGNMENTMMC 723 SYSTEM WIDE KEY ASSIGNMENTSMMC 851 SYSTEM ALARM REPORTINGMMC 853 MAINTENANCE BUSYALARM CODE DEFINITIONSALMNO.ALMCODE ALARM DEFINITION01 MJA01 POR Restart MP restart process has been executedvia power on restart (POR).02 MJA02 Button Restart MP restart process has been executedvia button reset or MMC 811.03 MJA03 Mem ResetThe system RAM has been cleared viamanual programming WebManagement resulting in a systemreset.04 MJA04 Watchdog Reset The MP has reset (Watchdog Reset)05 MJA05 LCP Reset An LCP has reset06 MJA06 PCM Switching A fault has occurred in the SwitchingControl.MJA10 S/W Exception Err Other kinds of System Restarts08 MJB01 HDLC Com Error Communications to Expansion ControlProcessor lost or faulty.09 MJB02 Memory Alarm 1 A RAM diagnostic check error hasoccurred in the MP.10 MJB03 Memory Alarm 211 MJB04 Memory Alarm 312 MJB05 Memory Alarm 413 MJB06 IPC MSGQ Over The IPC message queue is over 80% full14 MJB07 Task MSGQ Over The IPC message queue is now backunder 80% full15 MJC01 DTMF Fault An abnormal interrupt has occurred inthe system DTMF resources.