Chapter 33-102F-3-6663.5.6.13 Removing the Developing Rotary StopperSolenoid 0007-88751) Remove the 3 screws [1], and detach the motor base [2] from the rotarydrive assembly.F-3-6672) Remove the screw [1], and detach the developing rotary stopper solenoid[2] from the rotary drive assembly.F-3-6683.5.7 Density Detection PCB3.5.7.1 Removing the Rear Cover 0007-85511) Disconnect the cable [1] of the power supply assembly.2) Open the face-up cover [2], and remove the 4 screws [3] of the rear cover.F-3-6693) Open the reader assembly [4], and lift to free the 2 claws [5].F-3-6704) Close the reader assembly; then, detach the rear cover[1].F-3-6713.5.7.2 Removing the Reader Assembly 0007-85691) Open the reader assembly, and remove the left and right E-rings [1]; then,pull out the pin [2].F-3-672When closing the reader assembly, be sure to push in the arm [1] first.[1][2][1][1][2][1] [2][2][3][1][3][4][5][2][3][1][3][2][1][2][1]