Chapter 33-43F-3-2723.2.18.14 Removing the Lower Case Assembly 0008-27391) Remove the screw [1], and disconnect the 5 connectors [2].F-3-2732) Remove the screw [1] from the left side of the machine.F-3-2743) With care, shift down the machine to the left; then, remove the 8 screws[2] from the bottom, and detach the lower case assembly [3].F-3-275When you shift down the machine, be sure to take care to avoid injury by theedge of the side plate. Also, be sure to hold it by its grip segment.Be sure to place a cushioning material (g., towel) on the work table to protectthe protrusions of the machine from damage.Moreover, be sure to tape the opening of the laser scanner assembly to pre-vent intrusion of toner in the optical path of the assembly before shiftingdown the machine.If you must detach the lower case assembly, base user to hold it by its bottomso as to avoid injury by the edge of its side plate.3.2.18.15 Removing the Sub High-voltage Power SupplyBoard 0008-27401) Remove the connector [1] and the faston [2], and detach the 4 claws [3];remove the sub high-voltage power supply board [4].F-3-2763.2.19 Internal Temperature Detection Thermistor3.2.19.1 Removing the Rear Cover 0007-85651) Disconnect the cable [1] of the power supply assembly.2) Open the face-up cover [2], and remove the 4 screws [3] of the rear cover.F-3-2773) Open the reader assembly [4], and lift to free the 2 claws [5].F-3-2784) Close the reader assembly; then, detach the rear cover[1].[1] [1][1][1] [2][3][1][2][1][2][3][2][2][2][4][2][1][3][3][2][3][1][3][4][5]