Chapter 33-79F-3-523F-3-524When attaching the top cover, be sure to fit the link lever [2] while keepingthe drive release lever [1] in up position (i.e., with drive disengaged).F-3-525If you are fitting the drum cartridge in the machine with the top cover re-moved, be sure to do so with the drive release lever [1] fully in up position(i.e., with drive disengaged).If the drive release lever is in low position (i.e., with drive engaged), it forcesout the coupling [2], causing the coupling to interface with the drum car-tridge and to suffer damage.F-3-5263.5.1.8 Removing the Right Frame 0011-65951) Remove the 5 screws [1], and detach the right frame [2].F-3-5273.5.1.9 Removing the Shield Plate 0011-66161) Free the flat cable [1] from the connector.2) Remove the 6 screws [2], and detach the shielding plate [3].F-3-5283.5.1.10 Removing the Rotary Drive Assembly 0007-88351) Disconnect the 4 connectors [1], and remove the 2 screws [2].[1][2]OK NGEnlarged View of the Paper Retainer[3] [3][1][2][1][2][1][1][2][2] [2][3] [1]