e-STUDIO200L/202L/203L/230/230L/232/233/280/282/283 © 2004 - 2010 TOSHIBA TEC CORPORATION All rights reservedFIRMWARE UPDATING6 - 30Important:• Before updating the FAX ROM, make sure to print out the current Function list for mainte-nance, Function list (ADMIN), Phone book number information and Group number informa-tion. In case the updating is failed and the registered information of the users is lost for somereason, re-register the user information referring to the lists and recover it.• Confirm the following items before turning OFF the power of the equipment. Turning OFF thepower may clear the data below.- Confirm that the “MEMORY RX” LED is OFF and there are no memory reception data.- Print the “Mailbox/Relay box report” and then confirm that there are no F code data.- Press the [JOB STATUS] button to display the screen and then confirm that there are nomemory transmission data.(1) Install the ROM to the download jig.Make sure the direction is correct (P.6-4 "Fig. 6-3").(2) Turn OFF the power of the equipment.(3) Remove the cover plate.Fig. 6-32(4) Connect the download jig with the jig connector (CN602) on the FAX board.Fig. 6-33Cover plateConnector