e-STUDIO200L/202L/203L/230/230L/232/233/280/282/283 © 2004 - 2010 TOSHIBA TEC CORPORATION All rights reservedTROUBLESHOOTING5 - 40[EA40] Finisher front door open jamMJ-1022Is there any paper remaining on the transport path in the finisher or equipment? YES Remove the paper.NOIs the finisher connected with the equipment? NO Connect the finisher with the equipment.YESIs the connector J11 on the finisher controller PC board disconnected?Is the harness connecting the finisher controller PC board and joint sensor (S4) open cir-cuited? YES Connect the connector securely. Replace the harness.NOIs the joint sensor working properly?lNO 1) Connect the connector of the joint sensor securely.2) Replace the joint sensor.YESReplace the finisher controller PC board.MJ-1025Is the finisher connected with the equipment?Are the upper cover and front door of the finisher closed?lYES 1) Connect the finisher with the equipment.2) Close the cover and door of the finisher.NOIs any of the connectors CN4 (upper cover sensor and front door sensor) and CN8 (jointswitch) on the finisher controller PC board disconnected?Is the harness connecting the finisher controller PC board and each sensor (upper coversensor or front door sensor) open-circuited?Is the harness connecting the finisher controller PC board and joint switch (MS2) open-cir-cuited? YES Connect the connector securely. Replace the harness.NOAre the joint switch, upper cover sensor and front door sensor working properly? NO 1) Attach the actuator securely if its shaft is out of place.2) Replace the switch or sensor.YESReplace the finisher controller PC board.