© 2004 - 2010 TOSHIBA TEC CORPORATION All rights reserved e-STUDIO200L/202L/203L/230/230L/232/233/280/282/283ERROR CODE AND SELF-DIAGNOSTIC MODE2 - 1832486 Laser Timing of auto-clearing ofpolygonal motor pre-run-ning rotationALL 0<0-2>SYS Switches the polygonalmotor to the standbyrotation when a certainperiod of time haspassed from the pre-running. At this code,the period to switch thestatus to the standbyrotation is set.0: 15 sec.1: 30 sec.2: 45 sec.* This setting is effec-tive when “0” or “2”is set at 08-483.1488 Laser Setting of polygonal motortypeALL 0<0-3>M Set the type of polygo-nal motor.0: 2-clock type1: 3-clock type2: 4-clock type3: 4-clock type1489 Laser Polygonal motor rotationnumber on standbyALL 5<0-5>M 0: 38,090.55 rpm1: 35,000 rpm2: 30,000 rpm3: 25,000 rpm4: 20,000 rpm5: 10,000 rpm1490 Laser Polygonal motor rotation inthe energy saving modeALL 0<0-1>M 0: Stopped1: 10,000 rpm1491 Transfer Transfer charger bias cor-rection (H) at duplexingALL 149<0-255>M Corrects the transfercharger bias outputvalue of the leadingedge area of paper atduplexing.1492 Transfer Transfer charger bias cor-rection (C) at duplexingALL 139<0-255>M Corrects the transfercharger bias outputvalue of the center areaof paper at duplexing.1493 Transfer Transfer charger bias cor-rection (L) at duplexingALL 128<0-255>M Corrects the transfercharger bias outputvalue of the trailingedge area of paper atduplexing.1502 Image Error diffusion and dithersetting at photo modePPC 1<0-1>SYS Sets the image repro-duction method atphoto mode.0: Error diffusion1: Dither1503 UserinterfaceDefault setting of densityadjustmentPPC 0<0-1>SYS 0: Automatic1: Manual (Center)1Setting mode (08) Code Classifi-cation Items Func-tionDefaultablevalue>RAM Contents Proce-dure07/11 PreviousNext |