March 2000 © TOSHIBA TEC 11-29 DP120F/DP125F Troubleshooting1.6.2 SET FUNCTION [MENU], [9], [5], [02]This sets basic functions of this machine in general functions, telephone functions (for eachcountry/region), dialing functions, access digits, etc. Each table lists the applicable functionsfor 8 bits. The setting operation is performed by entering 1 or 0 in each bit to set its function.The following shows the functions that can be set. For further details, refer to “Service Settingin Test Mode” in “Chapter 4 Function Settings” on page 4-59.The setting functions are as follows.• FUNC 0 to 39Parameters of general functions. (Refer to 4-61.)• PCFUNC 0 to 7Parameters related to PC interface functions. (Refer to 4-119.)• HOME 0 to 2Tables of data on scanning system. (Refer to 4-128.)• UAD 0 to 19, 2 UAD 0 to 19Parameters of special functions used to adjust the unit to the telephone specifications ofeach country/region. (Refer to 4-132 or 4-163.)• EX TYPE 1, 2 EX TYPE 1Parameters related to telephone exchange functions. (Refer to 4-160 or 4-191.)• ACC DGT 1 to 2, 2 ACC DGT 1 to 2Parameters related to access digits functions. (Refer to 4-161 or 4-192.)(1) Use the [ ↑ ] or [ ↓ ] key to select “02. SET FUNCTION”, and then press [ENTER] key.(2) Using the following keys, select the function to be set.• Press the [ENTER] key to set the parameter and display the next function’s parameter.• Press the [→] key to move the cursor to the next bit.• Press the [←] key to move the cursor to the previous bit. If already at bit 7 (left digit), the[←] key will display the previous function’s parameter.• Press the [0] key to set the selected bit to “0.”• Press the [1] key to set the selected bit to “1.”(3) After setting, press the [STOP] key to return to the stand by mode screen.← Displays the numeric value currently set (cannot bechanged).← Displays the numeric value to be entered now (can only bealtered at the point of the blinking cursor).SET FUNCTIONFUNC0 =XXXXXXXXXXXXXXXXBit 7 Bit 001/12