DP120F/DP125F Function Settings 4-84 March 2000 © TOSHIBA TECFUNC 16 Bit 7:The setting determines whether or not receiving terminal data is printed on receiveddocument.FUNC 16 Bit 6:The setting determines whether or not transmitting terminal data is recorded on re-ceived document.FUNC 16 Bit 5:The setting determines the placement of the printed TTI data. This setting is effectiveonly when bit 6 is set to 1 (ON).Default tableUS TYPE EUR TYPEBIT US TW SG HK DE GB IT BE NL FI ES AT CH SE DK NO PT FR AU7 0 0 0 0 0 0 0 0 0 1 0 0 0 0 0 0 0 1 06 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 15 0 0 0 0 0 0 0 0 1 1 0 1 0 0 0 0 0 0 04 1 1 0 0 1 1 1 1 1 1 1 1 1 1 1 1 1 1 03 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 02 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 01 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 00 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0• FUNC 16Bit76543210ContentsAdding RTI:0: Not added1: AddAdding TTI:0: Not added1: AddPrint position of TTI:0: Inside document1: Outside documentUndefinedUndefinedLink with UserFunction SettingYesYesYes——