DP120F/DP125F Function Settings 4-66 March 2000 © TOSHIBA TEC• FUNC 4FUNC 4 Bits 7 to 4 and Bits 3 to 0:This value is used to program the modem transmission db level. The smaller thevalue, the higher the transmission level becomes. If errors occur frequently or train-ing is not sent, the transmission level should be changed, as a rule.Default tableUS TYPE EUR TYPEBIT US TW SG HK DE GB IT BE NL FI ES AT CH SE DK NO PT FR AU7 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 16 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 05 1 1 0 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 14 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 13 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 12 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 01 1 1 0 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 10 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1Bit76543210ContentsTransmit Attenuator Value for Line 1 (except Dial transmission):0000 to 1111 ... counts up on every -1db.0000: 0db0001: -1db0010: -2db...1111: -15dbTransmit Attenuator Value for Line 2 (except Dial transmission):0000 to 1111 ... counts up on every -1db.0000: 0db0001: -1db0010: -2db...1111: -15dbLink with UserFunction Setting——