B3: Distributed systems - 840D sl only2.2 NCU linkExtended Functions82 Function Manual, 03/2013, 6FC5397-1BP40-3BA1Safety Integrated acceptance test and NCU linkThe Acceptance Test wizard (ATW) is generally used to perform the acceptance testseparately for each NCU. Only alarms on the home NCU of the axis are displayed for linkaxes. To make the ATW also check alarms for link axes, the ATW must be told the safety-relevant NCU connected via the NCU link. For this purpose, these must be entered in theNETNAMES.INI file on the PG/PCU on which the ATW runs.Example: Entries in the NETNAMES.INI file for NCU link with two safety-relevant NCUsAdapt file: NETNAMES.INI (excerpt)[own]owner = HMI_1[conn HMI_1]conn_1= NCU_1conn_2= NCU_2[param HMI_1]mmc_address = 1[param network][param NCU_1]nck_address= 192.168.214.2,LINE=10,NAME=/NC,SAP=030d,PROFILE=CLT1__CP_L4_INTplc_address= 192.168.214.2,LINE=10,NAME=/PLC,SAP=0201,PROFILE=CLT1__CP_L4_INTADDRESS2= 192.168.214.2,LINE=10,NAME=/CP,SAP=0501,PROFILE=CLT2__CP_L4_INTADDRESS10= 192.168.214.2,LINE=10,NAME=/DRIVE_00_000,SAP=0201,SUBNET=0000-00000000:000,PROFILE=CLT2__CP_L4_INTADDRESS11= 192.168.214.2,LINE=10,NAME=/DRIVE_03_003,SAP=0900,PROFILE=CLT2__CP_L4_INTADDRESS12= 192.168.214.2,LINE=10,NAME=/DRIVE_03_011,SAP=0B00,PROFILE=CLT2__CP_L4_INTADDRESS13= 192.168.214.2,LINE=10,NAME=/DRIVE_03_012,SAP=0C00,PROFILE=CLT2__CP_L4_INTADDRESS14= 192.168.214.2,LINE=10,NAME=/DRIVE_03_013,SAP=0D00,PROFILE=CLT2__CP_L4_INTADDRESS15= 192.168.214.2,LINE=10,NAME=/DRIVE_03_014,SAP=0E00,PROFILE=CLT2__CP_L4_INTADDRESS16= 192.168.214.2,LINE=10,NAME=/DRIVE_03_015,SAP=0F00,PROFILE=CLT2__CP_L4_INTname=Machine_1[param NCU_2]nck_address= 192.168.214.1,LINE=10,NAME=/NC,SAP=030d,PROFILE=CLT1__CP_L4_INTplc_address= 192.168.214.1,LINE=10,NAME=/PLC,SAP=0201,PROFILE=CLT1__CP_L4_INTADDRESS2= 192.168.214.1,LINE=10,NAME=/CP,SAP=0501,PROFILE=CLT2__CP_L4_INTADDRESS10= 192.168.214.1,LINE=10,NAME=/DRIVE_00_000,SAP=0201,SUBNET=0000-00000000:000,PROFILE=CLT2__CP_L4_INTADDRESS11= 192.168.214.1,LINE=10,NAME=/DRIVE_03_003,SAP=0900,PROFILE=CLT2__CP_L4_INTADDRESS12= 192.168.214.1,LINE=10,NAME=/DRIVE_03_011,SAP=0B00,PROFILE=CLT2__CP_L4_INTADDRESS13= 192.168.214.1,LINE=10,NAME=/DRIVE_03_012,SAP=0C00,PROFILE=CLT2__CP_L4_INTADDRESS14= 192.168.214.1,LINE=10,NAME=/DRIVE_03_013,SAP=0D00,PROFILE=CLT2__CP_L4_INTADDRESS15= 192.168.214.1,LINE=10,NAME=/DRIVE_03_014,SAP=0E00,PROFILE=CLT2__CP_L4_INTADDRESS16= 192.168.214.1,LINE=10,NAME=/DRIVE_03_015,SAP=0F00,PROFILE=CLT2__CP_L4_INTname=Machine_2ReferencesThe "Safety Integrated" function is described in detail in:Function Manual for Safety Integrated