4. Installing the Fixing Cleaning BeltInstall the fixing cleaning belt by reversing the steps used to remove it.1) Wind the cleaning belt around the cleaning belt take-up roller q twice to three times.When installing it to the front, be sure that the arm guide plate w is on the outsideof the take-up roller.At this time, check to make sure that the area coming into contact with the roller isimpregnated with oil.Figure 6-207Check to make sure that the fixing cleaning belt is not wound askew or it is not slackor wrinkled.In addition, make sure that the direction of winding and the orientation are as shownin Figure 6-203.2) After installing the fixing cleaning belt, move the one-way lever e in the direction ofthe arrow (Figure 6-208); then, turn it until all the slack has been removed from thefixing cleaning belt.Figure 6-208Be sure to reset the counter (*6*; ‘WEB’) to ‘0’ after replacing the fixing cleaningbelt.eqwCOPYRIGHT © 1997 CANON INC. CANON NP6350/NP6251 REV. 0 JULY 1997 PRINTED IN JAPAN (IMPRIME AU JAPON)CHAPTER 6 FIXING SYSTEM6-22Caution:Caution: