4) Remove the two mounting screws e used to hold the fixing cleaning belt assemblyin place, and open the fixing cleaning belt upper assembly r upward.Figure 6-2055) Remove the cleaning belt feeding roller t and the cleaning belt take-up roller y bypushing them toward the rear.Figure 6-206Be sure to remove the silicone oil collecting in the oil pan found under the cleaningbelt feeding roller.tyerCOPYRIGHT © 1997 CANON INC. CANON NP6350/NP6251 REV. 0 JULY 1997 PRINTED IN JAPAN (IMPRIME AU JAPON)CHAPTER 6 FIXING SYSTEM6-21Caution: