8. Positioning the Scanner Locking Solenoid (SL1)• Making Adjustments1) Remove the rear cover.2) Remove the multifeeder assembly.3) Adjust the stroke of the scanner locking solenoid once again so that it is as specified.Figure 3-515Scanner locking solenoid(SL1)E-ringStandard8.5 ±0.5 mm(from belowclamp to topof solenoid)Loosen these twoscrews to adjustonce again.COPYRIGHT © 1997 CANON INC. CANON NP6350/NP6251 REV. 0 JULY 1997 PRINTED IN JAPAN (IMPRIME AU JAPON)CHAPTER 3 EXPOSURE SYSTEM3-31