E6582175K-2311 Output parametersTitle CommunicationNo. Function UnitMinimumsetting unitPanel/CommunicationAdjustment range DefaultsettingUsersetting Reference 0667 Integral inputpower pulseoutput unit- - 0: 0.1kWh1: 1kWh2: 10kWh3: 100kWh1 6.33.1 0668 Integral inputpower pulseoutput widths 0.1/0.1 0.1-1.0 0.1 0669 Logic output/pulsetrain outputselection (OUT)- - 0: Logic output1: Pulse train output0 6.33.2 0676 Pulse train outputfunction selection(OUT)- - 0: Output frequency1: Output current2: Frequency command value3: Input voltage (DC detection)4: Output voltage (command value)5: Input power6: Output power7: Torque8: -9: Motor cumulative load factor10: Inverter cumulative load factor11: PBR (Braking resistor) cumulativeload factor12: Stator frequency13: VIA input value14: VIB input value15: Fixed output 1(output current 100% equivalent)16: Fixed output 2(output current 50% equivalent)17: Fixed output 3(Other than the output current)18: Communication data19: -20: VIC input value21, 22: -23: PID feedback value24-52: -53: PBR (Braking resistor) load factor0 0677 Maximum numbersof pulse trainoutputkpps 0.01/0.01 0.50-2.00 0.80 0678 Pulse train outputfilterms 1/1 2-1000 64 0679 Pulse train inputfilterms 1/1 2-1000 2 6.10.5 0681 Analog outputsignal selection- - 0: Meter option (0 to 1 mA)1: Current (0 to 20 mA) output2: Voltage (0 to 10 V) output0 5.16.33.3 0684 Analog outputfilterms 1/1 2-1000 2 0691 Inclinationcharacteristic ofanalog output- - 0: Negative inclination (downwardslope)1: Positive inclination (upward slope)1 0692 Analog output bias % 0.1/0.1 -1.0-+100.0 0.0 0693 Factory specificcoefficient 6E- - - - * 3 0699 Factory specificcoefficient 6F- - - -*3: Factory specific coefficient parameters are manufacturer setting parameters. Do not change the value of these parameters.