E6582175G-37Note 1) Multiple functions assigned to a single terminal operate simultaneously.Note 2) In case of setting always active function, assign the menu number to , and (alwaysactive function selection).Note 3) In case of using terminal S2 as a logic input, set the parameter =0 (logic input).Note 4) In case of using terminal S3 as a logic input, set the slide switch SW2 (lower) to S3 side and the parameter=0 (logic input).Note 5) In case of using terminal VIB as a logic input, set the side switch SW2 (upper) to S4 side and set theparameter =1,3, or 4 (logic input). Since/ source logic depends on the slide switch SW1.Input terminal selection 7 (VIB) of the logic input terminal function is enabled only by an even numbersetting (Positive logic). An odd number setting (Negative logic) is disabled.Note 6) In case of using terminal VIA as a logic input, set the parameter =3 or 4 (logic input).Note 7) When stable operation cannot be attained because of frequency setting circuit noise, increase the value of. Connecting1) For logic input2) For connection (sink logic) via transistor output Usage example ··· 3-wire operation (one-push operation)Use the 3-wire operation function to operate the inverter, maintaining operation without using the sequence circuitby inputting an external signal (reset logic signal).CCInput terminal ●Operates by short circuiting betweenthe input terminal and CC (common).Use for forward run, reverse run,preset-speed and so on.InverterRelay a-contact With sink settings● Control by connecting the input terminal andCC (common) to the output (non-logicswitch) of the programmable controller.Use for forward run, reverse run, preset-speed and so on. Use a 5 mA transistorthat operates at 24 V dc.Inverter Programmable controllerCCInput terminal