E6582175F-516[Setting of jog run mode (RES-CC)]Ex) Assign jog run mode to control terminal RES.Title Function Adjustment range Settingf113 Input terminal selection (RES) 0-203 18(Jog run mode)Note 1: During the jog run mode, low speed detection signal (LOW) is output but designated frequency reachsignal (RCH) is not output, and PID control does not work.Note 2: When only the operation panel is used for operation in jog run mode, the jog run function does not need tobe assigned to any input terminal.RES (JOG): ON + F:ON: Forward jog runRES(JOG): ON + R: ON: Reverse jog run( Frequency command + F: ON: Forward run , Frequency command + R: ON: Reverse run ) The jog run setting terminal (RES-CC) is enabled when the value of operation frequency is that of the jogrun frequency and below.This connection does not function when operation frequency exceeds the jog run frequency. The motor can be operated in jog mode while the jog run setting terminals are connected (RES-CC). Jog run has priority to new operation command given during operation. Even for f261 = 0 or 1, an emergency DC braking (f603 = 2) is prior to the setting. No limits are imposed to the jog run frequency by the upper-limit frequency (parameter ul).ST-CCF-CCR-CCRES-Frequency command inputReverseForwardForward0Set frequency(=18)Forward