36ROP.Setup.software. (continued)Configuring.the.Unit.Settings.[Configuration]Configure the settings of the unit in the [Configuration] tab.When you connect the personal computer to the unit for the first time,click the [REFRESH] button (2) to acquire the values set on the unit.12 53 41..Select.the.unit.(ROP).to.be.set.Click the in the setting target selection list box (1) to display theIP addresses of ROP units that can be set. From among these, selectthe IP address of the ROP you want to set.Any of the units registered on the [ROP List] tab can be selected.2..Update.the.[Configuration].tab.display.Click the [REFRESH] button (2) to acquire connection information setto the unit on the personal computer and update the [Configuration]tab display.3..Make.unit.settings.[SETTING ITEM] (3) is displayed for setting items of the ROPselected in procedure 1.Make settings for required items in the [DATA] column (4).RECEIVE.PORT.Set the port number for the unit to receive remote cameraconfiguration file update notifications from remote cameras.Possible setting range: 35200 to 35599DISPLAY.BRINGHTNESS.LED.Set the brightness of the panel LEDs.DISPLAY.BRIGHTNESS.SEGMENT.DISPLAY.Set the brightness of the panel 7-segment display.BUZZER.Enable or disable the buzzer (beep/call tone).FLARE/PED.Select the flare/pedestal control function.TALLY.ENABLE.Enable or disable tally outputTALLY.INPUT.Set which camera is selected for input of tally information to tallyinput.Possible setting range: Cam1 to Cam19TALLY.CONTROL(Camcoder.only)Specifies whether tally control is performed via panel operations orpreview terminal inputs..The settings above can also be made on the unit in setup mode.4..Confirm.the.settings.When the settings are complete, click the [SET] button (5) to confirmthem.When the [Do you agree to rebooting after data transfer?] messageappears, click the [OK] button.If you click [CANCEL], the settings are not reflected on the unit.Making.Camera.Connection.Settings.[Camera.List]On the [Camera List] tab, configure settings for connections betweenthe ROP and the cameras. When you connect the personal computer tothe unit for the first time, select the ROP to be set in the ROP list box (1)and click the [REFRESH] button. Values set on the ROP selected in thelist box (1) are acquired.Each of the [C01] to [C19] lines displays a list of the connection settinginformation for the corresponding camera number.112 13 1614 1524 35678910111..Select.the.ROP.for.which.you.want.to.make.connection.settings.Click in the selection list box (1) to display the IP addresses ofROP units that can be set. From among these, select the ROP whoseIP address you want to setAny of the units registered on the [ROP List] tab can be selected.2..Update.the.[Camera.List].tab.display.Click the [REFRESH] button (13) to acquire connection informationfor the ROP set in the selection list box (1) on the personal computerand update the [Camera List] tab display.3..Make.connection.settings.Connection setting information is displayed for the ROP selected inprocedure 1.Make settings for required items.Items that can be set and buttons that are enabled/disabled varyaccording to the CONNECTION MODE (2) setting..z With.the.serial.connection.mode24 3567CONNECTION.MODE.(2)Set the connection mode of the selected ROP.To select the serial connection mode, select the [Serial Mode]button .Serial Mode: Make serial mode connection settings.IP Mode : Make IP connection mode settings.CAMERA.TYPE.(SERIAL).(3)Set the device to be connected by serial connection. Select theconnection device.CCU : Serial connection is used with the CCU.Remote Camera : Serial connection is used with the remote camera.Camcoder : Serial connection is used with the camera recorder.CAMERA.NUMBER.(SERIAL).(4)Set the camera number of the device to be connected by serialconnectionsThese settings are not possible in IP connection mode.