16Setup.Mode.Operations.(continued)12.Set.default.gateway1..Press..to.select.menu.number.[12].•Block 1 of the default gateway appears.CAMERANo.DATASETDISPLAY SELECTUPDOWNSET UPND/CCM.GAIN/M.PEDSHUTTERNDM.GAINIRISM.PED10-19CCSHTSYNCSELECTEXECUTEEXITSAVE/LOADSHIFT+UP+DOWNPress to select themenu numberPress to select thedefault gatewayPress to switch the blockPress to confirmPress to exit setup mode (hold down)Display/set block 1Display/set block 2Display/set block 3Display/set block 42..Press..to.select.[CC],.[SHT],.and.[SYNC].•The display changes in the order of block 1, block 2, block 3, andblock 4.•When changing the default gateway, press or tochange the setting for each block.NDM.GAINIRISM.PEDCCSHTSYNC3..Press..to.confirm.the.default.gateway.setting.•Pressing while block 4 is displayed confirms thesetting.NDM.GAINIRISM.PEDCCSHTSYNC•To exit setup mode, hold down for about 2 seconds.•If the default gateway setting value has been changed, the unit willrestart automatically when you exit setup mode. If the setting valuehas not been changed, the unit will not restart.•To make other settings, press Settable.addresses192.168.0.130Block 1Block 2Block 3Block 4For the IP address, you can set a value within the following ranges.Block 11 to 223Block 20 to 255Block 30 to 255Block 41 to 254However, “127.0.0.1” cannot be set even though it is within the aboveranges.For the subnet mask, you can set a value within the following ranges.Block 10 to 255Block 20 to 255Block 30 to 255Block 40 to 255However, “0.0.0.0” and “127.0.0.1” cannot be set even though it iswithin the above ranges.For the default gateway, you can set a value within the followingranges.Block 10 to 255Block 20 to 255Block 30 to 255Block 40 to 25513.Set.port1..Press..to.select.menu.number.[13].•The 3 digits of the port number appear.CAMERANo.DATASETDISPLAY SELECTUPDOWNSET UPND/CCM.GAIN/M.PEDSHUTTERNDM.GAINIRISM.PED10-19CCSHTSYNCSELECTEXECUTEEXITSAVE/LOADSHIFT+UP+DOWNFirst 3 digitsLast 2 digitsPress to select themenu numberPress to selectthe portPress to switch the blockPress to confirmPress to exit setup mode (hold down)2..Press..to.select.[CC].•The display changes to the next 2 digits.NDM.GAINIRISM.PEDCCSHTSYNC•Press or to change the setting for each block.•Press to confirm the setting.•A value within the range of 35200 to 35599 can be set for the portnumber.•To exit setup mode, hold down for about 2 seconds.•If the port number setting value has been changed, the unit will restartautomatically when you exit setup mode. If the setting value has notbeen changed, the unit will not restart.•To make other settings, press 14.Save/load.remote.camera.configuration.fileThe data recorded by the remote camera can be saved to a memorycard.Press..to.select.menu.number.[14].CAMERANo.DATASETDISPLAY SELECTUPDOWNSET UPND/CCM.GAIN/M.PEDSHUTTERNDM.GAINIRISM.PED10-19CCSHTSYNCSELECTEXECUTEEXITSAVE/LOADSHIFT+UP+DOWNPress to select themenu numberSelect y (Execute)/n (Cancel)Save/load selection confirmationSave indicationLoad indicationPress to confirmPress to exit setup mode (hold down)