E6581595B-322.2.1 Standard connection diagram 1This diagram shows a standard wiring of the main circuit.MCCB*1R/L1S/L2T/L3U/T1V/T2W/T3FLCFLBFLAMotorFRS1S2CCP24OUTNOCCFM CC VI P5+ +--P0 PA/+ PC/-Meter Voltage signal: 0-5V/0-10V(Current signal: 4-20mA)External potentiometer (1~10kΩ)Protective functionactivation outputRyVF-nC3PowercircuitNoisefilterDC reactor (DCL)*2 , *5 (option)ForwardReversePreset-speed 1Preset-speed 2CommonStandard connection diagram - SINK (Negative) (common:CC)7.5V-1mA(or 0-10V/4-20mA)MCCB(2P)R/L1S/L2Power supplySingle phaseLow-speedsignal outputMain circuit power supply1ph-120V class: single-phase 100-120V-50/60Hz1ph-240V class: single-phase 200-240V-50/60Hz3ph-240V class: three-phase 200-240V-50/60Hz*4: 1ph-240V models have noise filter inside.*3*4*1: The T/L3 terminal is not providedfor single-phase models.Use the R/L1 and S/L2 terminal asinput terminals.*2: The inverter is supplied with the POand the PA/+ terminals shorted bymeans of a shorting bar.Before installing the DC reactor (DCL),remove the bar.*3: When using the OUT output terminal insink logic mode, short the NO and CCterminals.ControlcircuitI MFrequencymeter(ammeter)Connector forcommon serialcommunicationsOperation panel*5: 1ph-120V models cannot be used withDC reactors.RS485communicationconnector*6: When external potentiometer isconnected by using P5 terminal,set the parameter = .efesotomasyon.com -Toshiba inverter,drive,servo,plc