E6581595F-186 Starting frequency Output frequency (Hz)0Operation signal (F-CC)TimeONOFF6.6 Operation frequency6.6.1 Starting frequency : Starting frequency setting• FunctionThe frequency set with is put out as soon as operation is started.Use the parameter when a delay in response of starting torque according to theacceleration/deceleration time is probably affecting operation. Setting the starting frequency to avalue from 0.5 to 3Hz is recommended. The occurrence of an overcurrent can be suppressed bysetting this frequency below the rated slippage of the motor.[Parameter setting]Title Function Adjustment range Default setting Starting frequency setting 0.1-10.0 (Hz) 0.56.6.2 Run/stop control with frequency setting signals : Operation starting frequency : Operation starting frequency hysteresis• FunctionThe Run/stop of operation can be controlled simply with frequency setting signals.[Parameter setting]Title Function Adjustment range Default setting Operation starting frequency 0.0- (Hz) 0.0 Operation starting frequency hysteresis 0.0- (Hz) 0.00 A B 100% Frequency command value + - When the frequency command signalreaches the B point, the inverteroperates.When decelerating, operation stopswhen the frequency setting signal is lessthan point A.Output frequency [Hz]efesotomasyon.com -Toshiba inverter,drive,servo,plc