USO RESTRITO62 Signal SelectionButton Number whenthe shift buttonis not pressedNumber whenthe shift buttonis pressedReentry buttons 121 to 123 125 to 127Chapter 3 Signal Selection and TransitionsNotesCross-point control block button numbers Buses for which operations can beinhibitedThis setting applies to the cross-point buttons in eachswitcher bank.If you make the setting for one cross-point button, thisinhibits operation of all cross-point buttons with the samenumber in the following buses.The corresponding name also disappears from the sourceYou can use the rightmost (24th) button as a [SIDE FLAG]button. In this case, the shift button moves one to the left,to the 23rd, and the button numbers are offset by one.For details about the [SIDE FLAG] button, 1 “Assigninga Cross-Point Button to Enable/Disable Side Flags”(p. 333).Switching button numbersThe rightmost (24th) button functions as a shift button. Theshift button function can be disabled in the Setup menu.When selecting the signals of button numbers 1 to 23,press the cross-point button for the desired signal.To select button numbers 24 to 46, hold down the shiftbutton, and press the cross-point button for the desiredsignal.Interchanging the M/E and PGM/PSTBanksOn the ICP-6520/6530, you can use the M/E bankselection buttons on the cross-point control block tointerchange the M/E bank and PGM/PST bank.For example, if you press the [M/E1 SEL] button on thebank that is being used as PGM/PST, the bank will becomethe M/E-1 bank.At the same time, the bank that was being used as M/E-1will become the PGM/PST bank, effectively interchangingthe M/E and PGM/PST banks.The change will also be reflected in the M/E bank display.NotesOn the ICP-3000/3016, you cannot interchange banksusing control panel buttons.name display.• Background A, background B• Keys 1 to 4• Utility bus• DME external video busAssigning the function of disabling cross-point button operation to a buttonIn the Setup menu, assign “Inhibit Set” to any of thebuttons in the 1st row.For details, 1 “Assigning a Bus or Function to 1st RowButtons” (p. 340).Inhibiting operation of a cross-point buttonHold down the button to which “Inhibit Set” is assigned,and press the cross-point button whose operation you wantto inhibit.The button you pressed flashes amber, and its operation isinhibited.NotesEven when you inhibit operation of a cross-point button,macro attachment settings are still possible.For details, 1 “Setting and Canceling a MacroAttachment” (p. 292).Clearing a cross-point button operationinhibit settingHold down the button to which “Inhibit Set” is assigned,and press the button whose operation is inhibited (flashingamber).This clears the operation inhibit setting for the button youpressed.Inhibiting Cross-Point ButtonOperationsFor each cross-point button, you can temporarily inhibitoperations.Clearing all operation inhibit settingsPress the button to which “Inhibit Set” is assigned and thebutton to which “Inhibit All Clear” is assignedsimultaneously.NotesThis setting is cleared when you reset the control panel.