USO RESTRITO374 Tally Group Settings / Wiring SettingsNo. Parameter Adjustment1 Destination(From)Destination start address2 Destination(To)Destination end address3 Destination(Level)Destination levelChapter 22 Router Interface and Tally SetupNo. Parameter Adjustment2 Destination Destination start address3 Level Level4 In the group, select [External Box2].5 In the group, select [32 × 1].6 Set the parameters.At this point, make the settings of Destination andLevel the same as in step 3.This automatically couples External Box1 andExternal Box2, forming an external box with 40(8+32) inputs.Setting the group number of an S-Busdescription nameSets the group number for an S-Bus description name to bedisplayed in the source name displays for a cross-pointoperation.1 In the group of the EngineeringSetup >Router/Tally >Router menu (7361), press [GpNo].2 Set the following parameter.No. Parameter Adjustment1 Gp No Group number of S-Busdescription namea)a) When setting values 1 to 7 are selected and the name is not set, thedescription name for “0” appears.If the description name for “0” is not registered either, the Type andNo values appear.3 In the group, press [Set].NotesTransmit the description name selected here from therouter.Tally Group SettingsWith the S-Bus protocol, tally control is possible forgroups 1 to 8, but in this system you can use either groups1 to 4 or groups 5 to 8.You can also select whether or not to transfer the tallyinformation over the S-Bus.Setting the tally groups1 Open the Engineering Setup >Router/Tally >GroupTally menu (7362).2 To select a consecutive sequence of groups from eachof groups 1 to 4 and groups 5 to 8, set [All GroupEnable] to On.3 In the group, select the desired groups.4 Set [SBus Tally Enable] to On to enable the tallyinformation on the S-Bus.Wiring SettingsWhen configuring a system in which the switcher inputsand outputs are connected to a router, setting thisconnection configuration (referred to as “wiring”) in the S-Bus space, or inputting the information which specifies thephysical wiring, is necessary.The settings are common to the parallel and serial tallies.Making New Wiring Settings1 Open the Engineering Setup >Router/Tally >Wiring>New menu (7363.1).2 Set the destination.When switcher inputs and outputs are connected to therouter in a group, you can specify the start and enddestination addresses.Destination From: Specifies the start destinationaddress for the wiring configuration.Destination To: When the wiring configuration ismultiple, specifies the end destination address. Fora single wiring connection, this setting is notrequired.Destination Level: Specifies the destination level ofthe wiring configuration. PreviousNext |