USO RESTRITO362InterfacingwithExternalDevicesChapter19SwitcherSetupTest firing the triggerPress [Test Fire].This outputs a trigger from the selected output port. This isno output when the trigger type is“Status.”Enabling or Disabling AUX BusControl1In the Engineering Setup >Switcher >Device Interfacemenu (7337), press [AUX Control].The AUX Control menu (7337.5) appears.2Select the 9-pin port for the setting from the group.Remote S1:Makes the settings for the Remote S1port.Remote S2:Makes the settings for the Remote S2port.3Select the AUX bus.4Select whether to enable or disable AUX bus controlfrom the group.Enable:Enables control of the port selected in step2.Disable:Disables control of the port selected in step2.Manual:Sets whether control of the port selected instep2is possible or not depend on the setting inthe Misc menu.5Repeat steps2to4as required to make the settings forother ports.Setting the AUX Bus Output andReentry InputYou can select the signal input to the DME (AUX busoutput) and the signal returned as the switcher primaryinput (reentry input).1Open the Engineering Setup >Switcher >DeviceInterface >DME SDI I/F menu (7337.7).2Select the DME channel to set.3In the to be assigned to the DME channel.Aux Bus:Sets the AUX bus.Re-Entry:Sets reentry.4Depending on the selection in step3, set the Aux busoutput or reentry output.5Press [Set].Repeat steps2to5as required.Selecting the Mode for Turning OffKeys upon Receiving the EditorCommandSelects the mode for turning off keys when an“AllStop”command is received from the editor.1In the Engineering Setup >Switcher >Device Interfacemenu (7337), press [Editor I/F].The Editor I/F menu (7337.8) appears.2Select one of the following modes.All:When an“AllStop”command is received, allkeys for the selected regions are turned off.Specified:When an“AllStop”command is received,among all the keys for the selected regions, onlythe keys specified by the editor are turned off.NotesWhen an“AllStop”command is received in theprocess of a transition, the keys selected for the nexttransition are also turned off.NotesWhen using the MVE-8000A, it is not possible toselect any of DME1 Ext In to DME8 Ext In.