USO RESTRITO368GPIOutputSettingsNo.ParameterAdjustment1FromSlotFirstportslot2FromPortFirstportnumber3ToSlotLastportslot4ToPortLastportnumberChapter21DCUSetup•Parallel Output Port:1 to 364Press [GPI Output Set].Releasing the Assignment of a GPIOutput Port1In the Engineering Setup >DCU >Output Config menu(7353), select what the setting applies to (DCU1 orDCU2) from the group.2In the group, if [GPI Output]is on, press it to turn it off.3Select the slot and port to which the setting applies.4In the group, press [NoAssign].GPI Output SettingsThis sets the trigger type and so on for each GPI output.Making DCU GPI Output Settings1In the Engineering Setup >DCU >GPI Output Assignmenu (7354), select what the setting applies to.2In the group, select the trigger type.(Rising Edge):The trigger causes the relaycontacts to be open-circuit or drives the outputhigh, and holds this state for the specified pulsewidth.(Falling Edge):The trigger causes the relaycontacts to be shorted or drives the output low, andholds this state for the specified pulse width.(Any Edge):Each time the trigger occurs, therelay contacts are alternately closed or opened, orthe output is switched between high and low.Status:Depending on the status, the relay contacts areclosed or opened, or the output is switchedbetween high and low.No Operation:The trigger has no effect on the relaystate or output level.3Select the pulse width and timing to be set.No.ParameterAdjustment3PulseWidthPulsewidth4TimingOutputtiminga)a)1: Field 1, 2: Field 2, 3: AnyWhen“”is selected as the trigger polarity, there isno Pulse Width setting. When“Status”is selected,there is no Pulse Width or Timing setting.4In the or DCU to handle the GPI output.NotesThe SCU2 setting is disabled.When the action set in the following step5is carriedout on the control panel selected here, this causes aGPI output. It is also possible to output errorinformation.When the DCU is selected, you can output errorinformation by means of the action set in step5.5In the list on the right, select the action.6Press [Action Set] to confirm the action selection.Selectable actions for various trigger types•When the trigger type is other than“Status”(The x in M/E-x is the M/E bank number, the x in DSKxis the DSK number, and the x in Keyx is the keynumber.)When Source Device is SCU: M/E-x Keyx SS ? Recall,P/P DSKx SS ? Recall, No ActionWhen Source Device is DCU: No Action•When the trigger type is“Status”(The x in M/E-x is the M/E bank number, the x in DSKxis the DSK number, and the x in Keyx is the keynumber.)When Source Device is SCU: M/E-x Keyx SS ? Recall,P/P DSKx SS ? Recall, M/E-x Keyx On, P/P DSKxOn, Error Make, Error Break, Keep Make, KeepBreak, Device Recording, No ActionWhen Source Device is DCU: Error Make, Error Break,No ActionTest firing the triggerPress [Test Fire].This outputs a trigger from the selected output port. This isno output when the trigger type is“Status.”