2.3 System Data Control2.3.1 PC ProgrammingDescriptionThis PBX can be programmed and administered using a PC. There are two programming methods:1. On-site Programming: System programming/diagnosis can be performed locally by connecting a PC tothe PBX directly.2. Remote Programming: System programming/diagnosis and data upload can be performed from a remotelocation.1. On-site Programming:Method DescriptionUsing the Serial Interface(RS-232C) portThe PBX has a Serial Interface (RS-232C) port which can be usedfor either system administration or SMDR (® 1.26.1 StationMessage Detail Recording (SMDR)).Using the USB port The PC is connected to the USB port of the PBX, or a USB port (USBModule) attached to a DPT.Using the LAN interface A CTI-LINK card must be installed.Using a modem throughan SLT port*1An RMT card must be installed. Assign the floating extension numberof the analogue remote maintenance (default: 599), and dial thisnumber from the PC to connect to the PBX.Using an ISDN TAinterface (64 kbps)through an ISDNExtension Line*1Assign the floating extension number of the ISDN remotemaintenance (default: 699), and dial this number from the PC toconnect to the PBX. The RMT card is not required for this method.This method is available only when a user-supplied ISDN TA thatsupports CAPI is used.*1 If remote access is disabled through system programming, then this on site programming cannot be done.2. Remote Programming:Method DescriptionUsing a modem (RMT card) An RMT card must be installed. The floating extension number ofthe analogue remote maintenance must be assigned (default: 599).PC programming, using a telephone connected in parallel with themodem, can be done in the following ways:• Direct AccessDial the DIL/DID/DDI number whose destination is the floatingextension number of the analogue remote maintenance.• Through DISADial the floating extension number of the analogue remotemaintenance using the DISA feature. (® 1.17.6 Direct InwardSystem Access (DISA))• Call TransferCall an extension (probably the operator), and request a transferto the floating extension number of the analogue remotemaintenance. (® 1.12.1 Call Transfer)346 Feature Guide2.3.1 PC Programming