2.2 System Configuration—Software180 Feature GuideConditions• The start times of the following time modes can be specified through PC programming aswell as PT programming ( Time Service Starting Time [102]).The start and end times of the following break modes can be specified through PCprogramming only.Note that if an end time is programmed for a break, the day mode will start or resume atthis time, as shown previously in "Visualization of Time Schedule for Tenant 1" example.If no end time is programmed, the break will continue until the start of the next time mode,as shown in Time Table 4 in "Visualization of Time Schedule for Other Tenants".• Time Service Switching Mode (Automatic/Manual) ButtonAny flexible button can be customized as the Time Service Switching Mode (Automatic/Manual) button.Feature Guide References1.8.1 Toll Restriction (TRS)1.18.2 Flexible Buttons2.2.3 Tenant ServiceUser Manual ReferencesUser Manual1.7.7 Time Service2.1.2 Time Service Mode Control2.2.5 Operator FeaturesDescriptionThis PBX supports separate operators for both the PBX and each tenant. Any extension orincoming call distribution (ICD) group can be designated as an operator. Operators are thedestination of Operator Calls.– Day 1 and 2– Lunch– Night– Break 1– Break 2– Break 3Type DescriptionPBX operator A different extension or ICD group can be assigned as a PBXoperator for each time mode ( Operator Assignment [006]).