Upgrading Your Server 9-29RemovalRemove the DIMM depending on the following procedure.NOTES: To remove the failed DIMM, check the error message appearing inPOST or NEC ESMPRO to identify the DIMM socket (group) inwhich the failed DIMM is installed. The server operates only when at least two DIMMs are installed.1. See the section "Preparing for Installation and Removal" described earlier to prepare.2. Pull out the server from the rack.3. Remove the logic cover.4. Open the clips at each end of the socket from which you remove the DIMM.The DIMM pops out of the socket5. Hold the DIMM by the edges, lift it away from the socket, and store it in an anti-staticpackage.6. Reinstall all parts removed in Steps 3 to 7.See installation procedures for detail explanations.7. Power on the server and verify that POST displays no error messages.If POST displays an error message, take a note on the message and see the POST errormessages listed in Chapter 8.8. Start the SETUP and select [Advanced] → [Memory Configuration] → [Memory Retest]→ [Enabled] to clear the error information of the removed DIMM. (See Chapter 4 fordetails.)9. Select "Yes" for [Reset Configuration Data] on the Advanced menu.This setting is required to change the hardware configuration data. See Chapter 4 fordetails.