LYNX Touch Installation and Setup Guide- 7 -Wiring ConnectionsFULL LINE SEIZURE CONNECTIONSRJ31X1234 5678RINGTIPINCOMINGPHONE LINETOPREMISES PHONESINCOMINGPHONE LINETOPREMISESPHONESGREENREDGREY BROWNRINGTIPDIRECTCONNECTCORDOROR8-POSITIONJACK5000-100-094-V2H/S TH/S RRINGTIPBROWNGREYREDGREENMake Earth Ground Connection - The designated earth groundterminal EGND must be terminated in a good earth ground for thelightning transient protective devices in this product to be effective.The following are examples of good earth grounds available atmost installations:Metal Cold Water Pipe - Secure a non-corrosive metal strap(copper is recommended) to the pipe that is electrically connectedand secured to which the ground lead is electrically connected andsecured.AC Power Outlet Ground - Available from 3-prong, 120VAC poweroutlets only. To test the integrity of the ground terminal, use athree-wire circuit tester with neon lamp indicators, such as the ULListed Ideal Model 61-035, or equivalent, available at mostelectrical supply stores.Make Phone Line Connections - For local or full line seizurefollow the appropriate steps below.Local Seizure1.2.3.4.c.d.e.f.a.b.c.a.b.a.Connect the incoming phone line to either the 8 position jack orterminals TIP and RING on the LYNX Touch as shown on theSummary of Connections.Connect the handset phone lines to terminals H/S T (TIP) andH/S R (RING) as shown on the Summary of Connections.terminals as shown in the diagram or plug into the 8-positionHardwired Zone Connections - One EOLR supervised zonesupports both open circuit and closed circuit devices and has aresponse time of 350msec. Maximum zone resistance: 300 ohms,plus EOLRNote: The hardwire zone cannot be used as a fire zone.HARDWIRED ZONE: If the EOLR is not at the end of theloop, the zone will not be properly supervised, and thesystem may not respond to an open circuit on the zone.Cut the incoming RING and TIP phone lines (typically red andgreen, respectively) and connect them to RJ31X terminals 4(red) and 5 (green).Connect the premises end of the cut RING and TIP wires toRJ31X terminals 1 (grey) and 8 (brown) respectively.Wire the flying leads of a Direct Connect Cord to the control'sphone terminals as shown in the diagram or plug into the8-position jack.Plug the Direct Connect Cord into the RJ31X jack.Full Line Seizure: The control must be placed in series with theincoming phone line. Plugging the Direct Connect Cord directly intothe RJ31X jack, allows the control to seize the phone line when analarm occurs and normal phone line usage by the premisesphones if the plug needs to be removed.Connect terminal EGND to a good earth ground as shown on theSummary of Connections.Connect sensors/contacts to the hardwired zone terminals GND(-) and HWZ1 (+). Refer to the Summary of Connectionsdiagram.Connect closed circuit devices in series in the high (+) side ofthe loop. The EOL resistor must be connected in series with thedevices, following the last device.Connect open circuit devices in parallel across the loop. The2000-ohm EOLR must be connected across the loop at the lastdevice.AC Power Connections - Connect the Power Supply to thereceptacle on the LYNX Touch.ORConnect wires from the Power Supply to +9VDC and EGNDterminals as shown on the summary of connections diagram.WIREGAUGEMAXIMUM DISTANCE BETWEENPOWER SUPPLY AND CONTROLUp to 11 feetUp to 20 feetUp to 26 feet# 22# 20# 18WIRING TABLE