LYNX Touch Installation and Setup Guide- 61 -Testing the System2. If the test is successful the system will send the Manual Trigger Test Report (E601) to the CentralStation. The test will not be recorded in the Event Log.3. The system will make eight attempts to test the dialer for the Primary and eight attempts to test theSecondary Central Station. If the test is unsuccessful the system will display a “Reporter Failure”trouble message after 9-17 minutes.Zone Discovery ModeZone Discovery mode requires Installer supervision when in use. The system is not fully operational for fire or life safetywhile Zone Discovery Mode is active.Zone discovery mode can be used to remotely view all zones that have been programmed in the system foroperation. The zones must have a response type programmed and in the case of RF zones, must also have aserial number programmed. All zones programmed (except for duress) will be displayed.Enter Zone Discovery1. With the System in the Installer Programming mode, select the “Test” button and then select the “ZoneDiscovery” button. The “Zone Discovery” button will be highlighted indicating that the mode is active.Exit Zone Discovery1. Enter an Off sequence. If you do not exit zone discovery mode manually, the system will automaticallyexit zone discovery mode in approximately 1-4 minutes dependent upon the number of zones that areprogrammed. The system beeps once and returns to the home screen.Rebooting the SystemThe Reboot function allows you to restart the system if required. To reboot the system perform the following:1. With the System in the Installer Programming mode, select the “Test” button and then select the“Diagnostics” button.2. The system advances to the next screen. Select the “Reboot” button. A confirmation screen will appear.3. Select “Yes”. The system will restart.Note: After the reboot sequence is complete it is recommended that you perform a “Walk Test” to verify that all transmittersare operational in the system.