LYNX Touch Installation and Setup Guide- 58 -System OperationEvent LogThe LYNX Touch Series event log is capable of recording and displaying up to 128 system events. The typeof events that can be recorded is selectable and is programmed in the System Type programming field. Theevent log can be reviewed by entering the Installer Programming or Master User Programming mode. Referto the LYNX Touch Series User Manual for additional information.Note: In the unlikely condition that the backup battery becomes fully discharged when AC power is lost, any system activity performed afterthe low battery notification will not be saved in the event log. Additionally, the panel will revert to the status condition as before the lowbattery notification.Contact ID® & SIA Event Log CodesCIDCode DefinitionSIACode Definition110 Alarm, Fire AT/AR AC Trouble/AC Restoral121 Alarm, Duress BA/BR Burglary Alarm/Burglary Restoral122 Alarm, Silent CA/CD Automatic Closing/Closing Delinquent123 Alarm, Audible CI Fail to Close (Log only)131 Alarm, Perimeter CL Closing Report132 Alarm, Interior CQ Remote Closing134 Alarm, Entry/Exit CR Recent Closing135 Alarm, Day/Night DF/DR Door Forced/Door Restoral137 Alarm, Tamper EA Exit Alarm145 Expansion Module Tamper ES/EJ Expansion Device Tamper/Expansion Tamper Restore146 Silent Burglary ET Expansion Trouble150 24-Hour Non-Burglary FA Fire Alarm162 Carbon Monoxide Detected FT/FJ Fire Trouble/Fire Trouble Restore301 Trouble, AC Loss HA/HR Holdup Alarm/Holdup Restoral302 Trouble, Low System Battery GA/GR Gas Alarm/Gas Restoral305 Trouble, System Reset FT/FJ Fire Trouble/Fire Trouble Restore316 System Tamper* LT/LR Phone Line Trouble/Phone Line Restoral341 Trouble, Case Tamper OA Automatic Opening344 Trouble, RF Receiver Jam Detect OC Cancel Report351 Trouble, Telco 1 Fault OP Opening Report353 Trouble, Long Range Radio Transmitter Fault OQ Remote Opening373 Trouble, Fire Trouble PA Panic Alarm374 Trouble, Exit Error Alarm RP Automatic Test380 Trouble, Sensor RX Manual Test381 Trouble, Loss of Supervision RF TA/TH Tamper Alarm/Tamper Alarm Restore383 Trouble, Sensor Tamper TJ Tamper Trouble Restore384 RF Low Battery TS/TE Test Start/Test End401 Open/Close by User TT Tamper Trouble403 Open/Close Automatic UA Untyped Zone Alarm406 Cancel UB/UU Untyped Zone Bypass/Untyped Zone Unbypass407 Remote Arm/Disarm UT/UJ Untyped Zone Trouble/Restore408 Quick Arm XG/XH RF Interference/RF Interference Restore441 Armed Stay XT/XR Transmitter Battery Trouble/Transmitter Battery Restoral455 Auto-Arm Failed YT/YR System Battery Trouble/System Battery Restoral459 Recent Close570 Zone/Sensor Bypass601 Manual Trigger Test Report602 Periodic Test Report606 Listen-in to follow607 Walk Test623 Event 90% Full627 Program Mode Entry (Logged in Event Log Only)628 Program Mode Exit (Logged in Event Log Only) *If APL is enabled, AlarmNet will generate a special comm. failmessage (E316) if it does not hear from a unit within 15 minutesafter a delayed alarm is delivered. This message is meant to alertthe Central Station that the system has been tampered with andmay have been compromised.654 System Inactivity655 Reset Master Code (Logged in Event Log Only)759 Resident Monitor Zone Response760 Resident Response Zone Response761 General Monitor Zone Response762 General Response Zone Response