LYNX Touch Installation and Setup Guide- 69 -Zone Programming Default ValuesZone Assignment/Alarm Response Types for Values 3 and 4ZoneNumberLoopNumber Device Type Response Type Report Chime Supervision/Input Type Zone Descriptor1 --- New n/a Yes No EOLR n/a2 2 Door Entry Exit 1 Yes Yes Supervised Front3 2 Door Entry Exit 1 Yes Yes Supervised Back4 2 Window Perimeter Yes No Supervised n/a5 2 Window Perimeter Yes No Supervised n/a6 2 Window Perimeter Yes No Supervised n/a7 2 Window Perimeter Yes No Supervised n/a8 1 Motion Sensor Interior w/Delay Yes No Supervised n/a9 1 Smoke Detector Fire No Verification Yes No Supervised n/a46 1 New Not Used No Yes Supervised Main47 1 New Not Used No Yes Supervised Main48 1 New Not Used No Yes Supervised Main49 3 4 Button Key Arm Away Yes No Button n/a50 2 4 Button Key Disarm Yes No Button n/a51 4 4 Button Key No Response Yes No Button n/a52 1 4 Button Key No Response No No Button n/a53 3 4 Button Key Arm Away Yes No Button n/a54 2 4 Button Key Disarm Yes No Button n/a55 4 4 Button Key No Response Yes No Button n/a56 1 4 Button Key No Response No No Button n/a80 n/a Temperature Not Used Yes No High Temp n/a81 n/a Temperature Not Used Yes No Low Temp n/a82 n/a Temperature Not Used Yes No High Temp n/a83 n/a Temperature Not Used Yes No Low Temp n/a84 n/a Temperature Not Used Yes No High Temp n/a85 n/a Temperature Not Used Yes No Low Temp n/a95 --- Fire Fire No Verification Yes No Panic Trigger n/a96 --- Medical n/a Yes No Panic Trigger n/a97 --- --- Yes No Cover Tamper n/a99 --- Police 24-Hour Silent Yes No Panic Trigger n/aNOTE: Zone 1 is a hardwire zone; Zone 2 to 48 are RF zones (Zones 46 to 48 are reserved for Garage DoorZones); Zone 92 is Duress; Zone 99 is keypad panicZone Response Type MatrixDevice TypeResponse TypeEntry Exit 1Entry Exit 2PerimeterResident MonitorResident ResponseGeneral MonitorGeneral ResponseDay/NightInterior FollowerInterior With DelayFire No VerificationFire With VerificationCarbon Monoxide24 Hour Auxiliary24 Hour Audible24 Hour SilentMonitorNot UsedArm StayArm AwayDisarmNo ResponseSilent BurglaryGarageGarage MonitorTroubleDoor x x x x x x xWindow x x x x x x xMotion Sensor x x x x x x x xGlass Break x x x x xSmoke Detector x xHeat Sensor xCarbon Monoxide Detector xTemperature x x x x x xFlood x xEnvironmental x x x x x xMedical x x xFire x xPolice x x x xGarage Door x xOther x x x x x x x x x x x x x x x x x x x x x x x x x x