LYNX Touch Installation and Setup Guide- 29 -Programming the ControlProgram ZonesThe following system options are programmed in this section:Option FunctionSerial Number Manually enter device serial number or enroll via RF transmissionLoop Number Manually enter device loop number or enroll via RF transmissionZone Description 1/2 Enter Zone Descriptors for the device being enrolledDevice Type Select the type of device being enrolledResponse Type Select the alarm response for the device being enrolled (refer to Zone Response Type Table)Alarm Report Activate reporting option for the device being enrolledChime Enable/disable chime mode for specific device being enrolled (applies to Entry/ Exit, Perimeter, andInterior Response types only)Supervision Select supervision for device being enrolledNote: If applicable, preprogrammed defaults for the LYNX Touch Control are shown on the screen unless otherwise noted.SCREEN ACTION5000-100-133-V0Zones 1. Select “Zones”The System displays the following options:1. New3. Back Door5. Motion Sensor2. Front Door4.Window6.New2. Use the down T arrow to scroll to the next page of options. Use the S arrow to return tothe previous page.7. – 45. New46. – 48 New (Main) (reserved for Garage Door Zones)49. – 56. 4 Button57. – 64. New80. – 85. Temperature (Z-Wave Thermostat zones)95. Fire96. Medical99. Police3. Select a zone and then select “Edit” or “Add New” to program the next available zone. Thefollowing options are displayed (dependant upon Zone Type):Serial Number * Loop Number * * This field does not apply toHardwire Zone 1 orTemperature Zones 80-85.Zone Description 1 Zone Description 2Device Type Response TypeAlarm Report Chime Supervision4. Select an option to display the next programming field.Serial Number Serial Number (This field does not apply to Temperature Zones 80-85)When “Serial Number” has been selected “Enter Serial Number or Activate” is displayed. Thetransmitter serial number and loop number can be enrolled via RF transmission OR manually.Enroll via RF Learning To enroll the device using RF Learning mode three transmissions(open/close) of the device will be required. The initial transmission activates the RF Learningmode and the system will emit a single beep. A second transmission enrolls the serial numberand the system beeps two times and displays “Activate Sensor Again To Confirm”. A thirdtransmission will confirm the serial number. The system beeps two times and returns to theZone programming Screen.Enroll ManuallyEnter the 7-digit serial number printed on the transmitter using the displayed keypad andselect “Done”. The system beeps one time and returns to the Zone programming Screen.Loop Number1Loop Number (This field does not apply to Temperature Zones 80-85)Select “Loop Number” to toggle between 1, 2, 3 and 4. Enter Save.Zone Description 1 Zone Description 1/Zone Description 2When programming the Zone Description, after entering the first letter of the description on thekeypad you can use the up S and down T arrows to scroll through the availablepreprogrammed zone descriptions. For a list of the pre-programmed Zone Descriptors, pleasevisit http://www.security.honeywell.com/hsc/resources/MyWebTechSelect “Zone Description 1 or Zone Description 2”. Using the displayed keypad enter ZoneDescription 1 or Zone Description 2. The system announces the Zone Description. Enter“Done”, when you are finished. The system returns to the Zone Programming page.