LYNX Touch Installation and Setup Guide- 20 -Zone Response Type DefinitionsGeneral InformationDuring programming, you must assign a zone type to each zone, which defines the way in which the systemresponds to faults in that zone. Zone types are defined below.Type Function CharacteristicsNot Used Used to program a zone that is not used. • NoneEntry/Exit 1(Burglary)Usually assigned to sensors or contacts onprimary entry and exit doors.• Entry delay #1 is programmable.• Exit delay is independently programmable.• Exit and entry delays when armed in AWAY or STAY mode.• No entry delay when armed in STAY INSTANT or AWAY INSTANTmode.• Exit delay regardless of the arming mode selected.Entry/Exit 2(Burglary)Usually assigned to sensors or contacts onsecondary entry and exit doors that might befurther from the keypad (typically used for agarage, loading dock, or basement door).• Entry delay #2 is programmable.• Exit delay is independently programmable.• Secondary entry delay, if armed in the AWAY or STAY mode.• No entry delay when armed in the STAY INSTANT or AWAYINSTANT mode.• Exit delay begins regardless of the arming mode selected.Perimeter(Burglary)Usually assigned to all sensors or contacts onexterior doors and windows• Instant alarm, when armed in AWAY, STAY, STAY NO DELAY, orAWAY INSTANT mode.Interior, Follower Usually assigned to a zone covering an entry area(i.e.: foyer, lobby, or hallway) that one must passupon entry (after faulting the entry/exit zone) toreach the keypad. It provides an instant alarm ifthe entry/exit zone is not violated first, and protectsan area in the event an intruder has hidden on thepremises before the system is armed, or gainsaccess to the premises through an unprotectedarea.• Delayed alarm (using the programmed entry/exit time) if entry/exit(types 01 or 02) or interior-with-delay (type 10) zone is faulted first.• Instant alarm in all other situations.• Active when armed in AWAY or AWAY INSTANT mode.• Bypassed automatically when armed in STAY or STAY INSTANTmode.Trouble by Day/Alarm by NightUsually assigned to a zone that covers a sensitivearea (i.e.: stock room, drug supply room, etc.) Itcan also be used on a sensor or contact in an areawhere immediate notification of an entry is desired.• Instant alarm, when armed in AWAY, STAY, STAY INSTANT, orAWAY INSTANT (night) mode.• Provides a latched trouble sounding from the keypad and, if desired,a central station report when disarmed (day).24-hour SilentAlarmUsually assigned to a zone containing anEmergency button (silent emergency).• Sends a report to the central station but provides no keypad displayor sounding.• In disarmed state sends a report to the central station displays "NotReady to Arm" on the keypad and “AWAY”, “STAY” and “TOOLS”buttons are disabled.24-hour AudibleAlarmUsually assigned to a zone containing anEmergency button (audible emergency).• Follows sounder timeout• Sends a report to the central station, and provides alarm sounds at thekeypad.24-hourAuxiliary AlarmUsually assigned to a zone containing a buttonfor use in personal emergencies or to a zonecontaining monitoring devices (i.e.: water ortemperature sensors, etc.).• Sends a report to the central station and provides an alarm sound atthe keypad. (There is no keypad timeout.)Interior with Delay Provides entry delay (using the programmed entrytime), if tripped when the panel is armed in theAway mode. Bypassed when the panel is armed inthe STAY or STAY INSTANT mode.• Entry delay #1 (with programmed entry time) when armed in theAWAY mode.• Entry delay begins whenever sensors in this zone are violated,regardless of whether an entry/exit delay zone was tripped first.• No entry delay when armed in the AWAY INSTANT mode.• Exit delay regardless of the arming mode selected.Fire No Verification Can be assigned to any wireless zone used as afire zone. This zone type is always active andcannot be bypassed.• Alarm sound will pulse when this zone type is alarmed.Fire withVerificationCan be assigned to any wireless zone used as afire zone. Fire with verification is available withsmoke detector device type. It can not be usedwith heat detectors, combination heat/smokedetectors, wireless sensors or fire pull stations.This zone type is always active and cannot bebypassed.• Alarm sound will pulse when this zone type is alarmed. Only after thealarm has been verified.• System verifies alarm by delaying reporting and control panel alarmsounding for 30 seconds after alarm is detected. If the zone remainsfaulted after 30 seconds a fire alarm is provided. If any other firezone is faulted during the 30 second delay window a fire alarm isimmediately provided for that zone. An alarm for original fire zone willalso be provided if that zone is still faulted afterward. If there are nofire alarms after the 30 second delay expires, the system will open a60 second window. If any fire zone is faulted during that window afire alarm will immediately be provided for that zone.24-hour CarbonMonoxide MonitorCan be assigned to any wireless zone with a carbonmonoxide detector. This zone type is always activeand cannot be bypassed.• Local keypad and detector will sound when this zone type is alarmed.(Pulse Temporal 4)