LYNX Touch Installation and Setup Guide- 40 -Programming the ControlSystem SettingsThe following system options are programmed in this section:Option FunctionEntry Delay1/Entry Delay 2 Selects an Entry Delay time in seconds. The system will wait the time entered beforesounding alarm upon entering if system is not disarmed.Note: The Default values differ for the LYNX Touch and LYNX Touch SIA controls.Exit Delay Selects an Exit Delay time in seconds for both Entry Delay 1 and 2 Zone Types. Thesystem will wait the time entered before sounding an alarm if the exit door is left open afterthe system has been armed.Note: The Default values differ for the LYNX Touch and LYNX Touch SIA controls.Backlight Timeout Enable or disable display backlight turnoff after 30 seconds.Quick Arm Enables or disables Quick Arm Mode. If enabled, security code is not required to arm thesystem. The user simply presses the AWAY button (ICON) and then selects the “QuickArm” button on the displayed keypad to arm the system.Quick Exit Enables or disables Quick Exit Mode. If enabled allows the user restart the exit delay toallow entry or exit when the system is armedRestart Exit Time Enables or disables Restart Exit Time Mode. This option allows the control to restart theexit delay time after arming in STAY mode by entering the User Code and pressing theSTAY key (if quick arming is disabled) or by pressing the STAY key (if quick arming isenabled). This option also enables automatic exit delay reset, which resets exit delay if theentry/exit door is re-opened and closed before exit delay time expires after arming.Force Bypass Enables or disables Force Bypass Mode. All zones bypassed by this function will bedisplayed after the bypass is initiated. The Fire and CO Zones are not bypassed in theLYNX Touch.Exit Warning Enables or disables Exit Warning sound. Audible Exit Warning sound consists of slowcontinuous beeps until last 10 seconds, when it changes to fast beeps. The warning soundwill end at the termination of exit delay.Note: This field is not programmable in the LYNX Touch SIA and is always enabled.Auto Stay Arming Enables or disables Auto Stay Arming Mode. If this feature is enabled and the control panelhas been armed “Armed Away” at the LYNX Touch keypad or RF keypad, the system willswitch to the “Armed Stay” mode if the Exit Time has expired and no exit has been made.Lack of Usage Notify Enables or disables Lack of Usage Notification feature. If enabled, notifies the centralstation if an end user is not operating their security system by sending a System Inactivityreport 654. The report will be sent only to the Primary phone number and only if ContactID® format was selected.Power-Up in Previous Enables or disables Power-Up in Previous Mode feature. When the system powers uparmed, an alarm will occur 1 minute after arming if a zone is faulted. For the LYNX Touchcontrol any bypassed zones will be unbypassed. For the LYNX Touch SIA any bypassedzones will remain bypassed.Display Alarm Cancel Enables or disables display of Cancelled Alarm.Display Exit Time Enables or disables display of Exit Time.Cross Zone Delay Sets the maximum amount of time in which two zones must be tripped in an armed systemto send an alarm message to the Central Station. If only one cross zone is tripped duringthis time, a trouble message (CID code 380) for that zone is sent to the Central Station.Cross Zone 1/Cross Zone 2 Select the zones that will be used for Cross Zoning