4–35COPYRIGHT © 1998 CANON INC. CANON NP6621 REV.0 FEB. 1998 PRINTED IN JAPAN (IMPRIME AU JAPON)MECHANICAL SYSTEM3. Removing the Blank Exposure Lamp1) Remove the blank exposure lamp. (See “Re-moving the Blank Exposure Assembly.”)2) Remove the four screws q, and disconnect theconnector w.Figure 4-4053) Disconnect the connector e.Figure 4-4064) Remove the three screws r, and remove theblank exposure lamp t.Figure 4-4074. Removing the Blank Shutter Sole-noid1) Remove the blank exposure assembly.2) Remove the blank top plate, and disconnect theconnector q. (See “Removing the Blank Expo-sure Assembly.”)3) Remove the E-ring w, and remove the link arme from the blank shutter.4) Remove the two screws r, and pull out theblank shutter solenoid.Figure 4-4085. Positioning the Blank Shutter Sole-noidAdjust the position of the solenoid so that bottomA is 9.5 ±0.5 mm on both sides when the solenoidis moved in the direction of ON. Do not force theshutter excessively.After the adjustment, check to make sure thatthe solenoid moves smoothly.Figure 4-409aFigure 4-409b3451 4 23A1 12