4–16 COPYRIGHT © 1998 CANON INC. CANON NP6621 REV.0 FEB. 1998 PRINTED IN JAPAN (IMPRIME AU JAPON)MECHANICAL SYSTEM5. Adjusting the Left/Right RegistrationMake adjustments so that the image position isas indicated in Figure 4-308 when the Test Sheet iscopied in Direct.a. Pick-Up from the CassetteTurn the screw q shown in Figure 4-307 toadjust the position of the cassette hook plate.standards: 0 ± 1.5 mm• CW direction: moves the paper in the direc-tion of – in Figure 4-308• CCW direction:moves the paper in the direc-tion of + in Figure 4-308Figure 4-307Figure 4-3081231(-) (+)0±1.5mm02468104. Removing the Separation Pad1) Fully open the right door. (Remove the tensiontape from the door.)Caution:Take care not to open the right door exces-sively.2) Remove the front right cover.3) Remove the vertical path guide q (upper; fourscrews).Figure 4-3054) Remove the two screws w, and remove theseparation pad unit e.Figure 4-306