4–32 COPYRIGHT © 1998 CANON INC. CANON NP6621 REV.0 FEB. 1998 PRINTED IN JAPAN (IMPRIME AU JAPON)MECHANICAL SYSTEM8. Points to NoteWhen installing the feeding roller q, make surethat the belt pulley w attached to the feeding rolleris toward the rear of the copier.Figure 4-3679. Removing the Separation Roller1) Open the right door, and remove the two mount-ing screws w from the separation roller assem-bly support plate q; then, remove the separa-tion roller together with the pressure arm.Figure 4-368Front of copier122 12) Remove the stop ring e, and remove theseparation roller r.Figure 4-36910.Points to NoteWhen installing the separation roller q, makesure that the D-cut in the roller collar is toward thefront of the copier.Figure 4-37043Front of copierRear1