In this section:Introduction .............................................................................. 9-1KXCI communications connections .......................................... 9-2Using KCon to configure KXCI ................................................. 9-3Starting KXCI and the GPIB command interpreter ................... 9-5Using KXCI............................................................................... 9-6Logging commands, errors, and test results ............................ 9-6Graphing the test results .......................................................... 9-9GPIB command set ................................................................ 9-10GPIB command reference ...................................................... 9-13Ethernet command reference ................................................. 9-49SMU default settings .............................................................. 9-50System Mode SMU default settings ....................................... 9-51Output data formats ............................................................... 9-52Status byte and serial polling ................................................. 9-54Sample programs ................................................................... 9-56GPIB error messages ............................................................. 9-58KXCI pulse generator commands .......................................... 9-59KXCI CVU commands ............................................................ 9-66Calling KULT user libraries remotely ...................................... 9-81IntroductionThe Keithley External Control Interface (KXCI) allows you to use an external computer to remotelycontrol the SMUs and pulse generator cards in the 4200A-SCS. You can use remote control over thegeneral-purpose instrument bus (GPIB) or ethernet. You define the type of communications in KCon(in the KXCI Settings options). When controlled by an external computer, the 4200A-SCS functionslike any other GPIB instrument.This section contains:• KXCI user interface: Describes how to use the KXCI user interface, which is used to control GPIBoperation.• GPIB command set: The command strings to control the source-measure operations of the4200A-SCS are summarized in three tables.• GPIB command reference: Provides detailed reference information on the command set.• Ethernet command reference: Describes the command set that can be used for Ethernetcommunications.• SMU default settings: Describes how to return the SMUs to their power-on default settings.Includes a table that lists the default settings.• Output data formats: Describes the format of the data string that returns measured readings tothe computer for both system mode and user mode.Section 9Keithley External Control Interface (KXCI)