ADEMCO Vista-128FB manuals
Vista-128FB
Brand: ADEMCO | Category: Security System
Table of contents
- Table Of Contents
- Table Of Contents
- SYSTEM OVERVIEW
- Zone
- Alarm
- Device Timer
- P HONE A CCESS & V OICE R ESPONSE C APABILITY
- ABOUT THE KEYPADS
- FUNCTIONS OF THE KEYPAD
- ENTRY/EXIT DELAYS
- SECURITY CODES & AUTHORITY LEVELS
- A UTHORITY L EVELS
- G ENERAL R ULES ON A UTHORITY L EVELS AND C HANGES
- To Exit User Edit Mode
- To Change a User' Code
- To Delete a User
- ACCESSING OTHER PARTITIONS
- lobby
- CHECKING FOR OPEN ZONES
- DISPLAYING ALL ZONE DESCRIPTORS
- bypassing protection zones
- Using the [3] STAY key
- ARMING PERIMETER ONLY
- Using the [2] AWAY Key
- ARMING ALL PROTECTION
- DISARMING AND SILENCING ALARMS
- USING THE KEYSWITCH
- CHIME MODE
- VIEWING CENTRAL STATION MESSAGES
- PANIC KEYS
- SPEED KEY (MACROS)
- E XECUTING
- ACCESS DOOR CONTROL
- USING #70 RELAY MENU MODE
- USING SCHEDULES
- PROGRAMMING DEVICE TIMERS
- EVENT LOG PROCEDURES
- TESTING THE SYSTEM
- FIRE ALARM SYSTEM
- Fire Display Lock
- TROUBLE CONDITIONS
- Power Failure
- RECOMMENDATIONS FOR PROPER PROTECTION
- R ECOMMENDATIONS F OR P ROPER I NTRUSION P ROTECTION
- EMERGENCY EVACUATION
- MAINTAINING YOUR SYSTEM
- Routine Care
- QUICK GUIDE TO SYSTEM FUNCTIONS
- SUMMARY OF AUDIBLE NOTIFICATION
- GLOSSARY
- INDEX
Vista-128FB
Brand: ADEMCO | Category: Security System
Table of contents
- Table Of Contents
- Table Of Contents
- Table Of Contents
- Table Of Contents
- conventions used in this manual
- general description
- SECTION 2: Partitioning
- Master Keypad Setup and Operation
- SECTION 1: General Description
- Grade A Mercantile Safe and Vault Listing Guidelines
- Installing the Keypads
- Installing External Sounders
- Auxiliary Relay Connections
- Figure 3-7: Wiring Auxiliary Relay for Alarm Activation
- Telephone Line Connections
- Wiring Burglary and Panic Devices to Zones 1-8
- Figure 3-10: 4-Wire Smoke Detectors
- Figure 3-11: Wiring a 333PRM to the Control
- Installing RPM Devices
- Figure 3-14: Polling Loop Connections to the Control Panel
- Wireless Zone Expansion
- Figure 3-17: Installing the 5881ENHC with Tamper Protection
- Figure 3-18: 5881 RF Receiver (cover removed)
- Installing Output Devices
- Installing a Remote Keyswitch
- Installing a 5140LED Indicator Module
- Installing a Remote Keypad Sounder
- Long Range Radio Connected to the J2 Triggers
- Installing the 4100APG Pager Interface
- Figure 3-26: Wiring the 4100APG Without the Serial Printer
- Access Control Using VistaKey
- Access Control Using the PassPoint Access Control System
- Event Log Connections
- Installing the Audio Alarm Verification Module
- Connecting the Transformer
- Earth Ground Connections
- Determining the Size of the Standby Battery
- Figure 3-33: Connecting the Backup Batteries
- SECTION 4: Programming
- Menu Mode Programming
- Index
- Zone Number Designations
- Zone Response Type Definitions
- Zone Input Type Definitions
- Programming the Control for the Pager
- Programming for ECP Long Range Radio
- SECTION 5: Data Field Descriptions
- pabx access code
- prevent zone xxx bypass
- checksum verification
- pager id number for supervision
- restore report timing
- rf transmitter check-in interval
- zone 5 audio alarm verification
- check or trbl display
- SECTION 6: Scheduling Options
- Time Window Definitions
- Open/Close Schedules Definitions
- Scheduling Menu Mode
- Time Windows
- Daily Open/Close Schedules
- Time-Driven Events
- Limitation of Access Schedules
- Temporary Schedules
- SECTION 7: Downloading Primer
- Getting On-Line with a Control Panel
- Direct-Wire Downloading
- SECTION 8: Setting the Real-Time Clock
- SECTION 9: User Access Codes
- Multiple Partition Access
- Adding a Master, Manager, or Operator Code
- Changing a Master, Manager, or Operator Code
- SECTION 10: Testing the System
- Burglary Walk-Test (Code + [5] TEST)
- Armed Burglary System Test
- Trouble Conditions
- To the Installer
- UL Installation Requirements
- UL365 Police Station Connected Burglar Alarm
- summary of system commands
- specifications
- TABLE OF CONTACT ID EVENT CODES
- Table Of Contents
- Table Of Contents
- User Scheduling Menu Mode
Vista-128FB
Brand: ADEMCO | Category: Security System
Table of contents
- Table Of Contents
- SYSTEM OVERVIEW
- Zones
- Alarms
- Using Schedules
- Master Keypad Operation
- ABOUT THE KEYPADS
- FUNCTIONS OF THE KEYPAD
- ENTRY/EXIT DELAYS
- General Information
- Authority Levels
- General Rules on Authority Levels and Changes
- To Exit User Edit Mode
- To Change a User's Code
- To Delete a User
- ACCESSING OTHER PARTITIONS
- Common Lobby Operation
- How User Codes Affect the Common Lobby
- CHECKING FOR OPEN ZONES
- DISPLAYING ALL ZONE DESCRIPTORS
- BYPASSING PROTECTION ZONES
- Quick Bypass
- ARMING PERIMETER ONLY
- ARMING ALL PROTECTION
- DISARMING AND SILENCING ALARMS
- USING THE KEYSWITCH
- CHIME MODE
- VIEWING CENTRAL STATION MESSAGES
- PANIC KEYS
- SPEED KEY (MACROS)
- Executing
- ACCESS DOOR CONTROL
- USING #70 RELAY MENU MODE
- Programming Temporary Schedules
- PROGRAMMING DEVICE TIMERS
- EVENT LOG PROCEDURES
- TESTING THE SYSTEM
- Testing Your System
- FIRE ALARM SYSTEM
- Fire Display Lock
- TROUBLE CONDITIONS
- Power Failure
- RECOMMENDATIONS FOR PROPER PROTECTION
- Recommendations For Proper Intrusion Protection
- EMERGENCY EVACUATION
- MAINTAINING YOUR SYSTEM
- Silencing Low Battery Warning Tones at the Keypad
- QUICK GUIDE TO SYSTEM FUNCTIONS
- SUMMARY OF AUDIBLE NOTIFICATION
- GLOSSARY
- INDEX
Vista-128FB
Brand: ADEMCO | Category: Security System
Table of contents
- Table Of Contents
- When the system-wide fields have been programmed, program all partition-specific
- PROGRAM FIELD CATEGORIES
- PROGRAMMING WITH #93 MENU MODE
- zone programming
- SERIES RF TRANSMITTER LOOP DESIGNATIONS
- ALPHA DESCRIPTOR VOCABULARY
- RELAY VOICE DESCRIPTORS AND CUSTOM WORD SUBSTITUTES VOCABULARY
- SYSTEM LAYOUT WORKSHEETS
- OUTPUT RELAYS WORKSHEETS
- SCHEDULING MENU PROMPTS
- SCHEDULING WORKSHEETS
- summary of connections